TM 10-3930-638-24&P
2-28. INSTRUMENT PANEL MAINTENANCE (cont)
e. Warning Lights and Diodes (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or
excessive heat and dont smoke when using it. Failure to do so
could cause serious injury. If you become dizzy while using
cleaning solvent, get fresh air immediately, and get medical
attention. If contact with skin or clothes is made, flush with large
amounts of water. If contact with eyes is made, wash eyes with
water immediately, and obtain medical aid immediately.
2
Electrical connectors and
Clean
Use cleaning solvent P-D-680 on
terminals (1, 2, 5 and 6)
connectors and terminals only
3
Lens (3)
Clean
Use clean, dry cloth
INSPECTION
4
Harness, connector and
Inspect
Replace if insulation frayed, or if
light assembly wires
conductors broken
TESTING
5
Isolation diode (6)
Test
Set ohmmeter to lowest resistance range,
and connect leads to terminals of diode
(6). Note reading, then reverse leads and
note reading. There should be one low
and one high reading. Replace diode if
readings are both low, both high, or
identical
INSTALLATION
6
Instrument panel, a. Isolation diode (6)
Push on
Connector (5)
far right side
b. Bulb (4)
Install
In socket (2)
c. Socket (2)
Position
From below instrument panel
d. Lens (3)
Position
On instrument panel top
e. Socket (2) and lens (3) Push together
While rotating lens 1/4 turn to secure
socket (2)
f. Wire leads (1)
Push on
Warning light terminals
2-138
|