TM  10-3930-638-24&P 2-18.   GAGES   MAINTENANCE a. Gage Bulb Replacement. This task covers replacement of fuel level gage and oil pressure gage bulbs. INITIAL   SETUP TOOLS EQUIPMENT   CONDITION None Paragraph Condition Description IGNITION switch in OFF position and MATERIALS/PARTS key  removed. Replacement  bulb 2-53h Noise baffle mat rod removed and mat pulled up and over instrument panel for access to bottom of instrument panel. KEY 1. Socket 2. Bulb 3.  Gage STEP LOCATION ITEM ACTION REMARKS REMOVAL 1 Instrument a.  Socket  (1) Remove Grasp and pull out panel, bot- b Bulb (2) Remove Discard tom INSTALLATION 2 Instrument a. Bulb (2) Install panel, bot- b. Socket (1) Install Push in until it snaps into position tom 2-95