4-3. FUEL SYSTEM MAINTENANCE (cont)
b. Fuel Injection Pump (cont).
EXAMINE FOR
SPECIFICALLY
STEP
LOCATION
ITEM
INSPECT
INSPECTION (cont)
22
d. End plate
X
X
Bottom surface
(cont)
plug (89)
e. Regulator
X
Free length of 0.633 to 0.667
spring
inch, rate of compression
10 pounds per inch
23
Governor
Solenoid frame
X
X
For cracks and swelling in
control
and arm
encapsulating material and
cover (22)
assembly (24)
looseness of screw terminals.
Use ohmmeter and check for
continuity. Replace if any
defects observed or if con-
tinuity not obtained