TM 10-3930-638-24&P
4-3. FUEL SYSTEM MAINTENANCE (cont)
b. Fuel Injection Pump (cont).
EXAMINE FOR
SPECIFICALLY
LOCATION
STEP
ITEM
INSPECT
INSPECTION (cont)
18
WARNING
cont)
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and don't breathe vapors. Do not use near open flame or exces-
sive heat and don't smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately, and obtain medical aid immediately.
e. Pumping
Hold rotor under clean oil and
plungers
insert plungers into their
(122)
bore. With your thumb and
forefinger over shoe slots,
tilt from side to side several
times to determine complete
freedom of movement. Re-
versing or interchanging ini-
tial positions may be neces-
sary as these are matched
parts. If plungers are sticking,
but not visibly damaged, clean
both plungers and bore with
a soft brush and cleaning sol-
vent P-D-680
4-108
|