3-30. HYDRAULIC LIFT SYSTEM MAINTENANCE (cont)
e. Lift Cylinder Assembly (cont).
REMARKS
ITEM
ACTION
STEP
LOCATION
DISASSEMBLY (CONT)
Remove and
13
Gland assem-
a . Plug (47)
discard
bly (46)
Remove and
b. O-ring (48)
discard
Remove and
c . Back-up ring
discard
(49)
Remove and
d. Seal (50)
discard
Remove and
e . Wiper (51)
discard
Remove and
f . Bearing (52)
discard
CLEANING
Dry cleaning solvent P-D-680 used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
w e l l ventilated area. Avoid contact with skin, eyes and clothes and
don-t breathe vapors. Do not use near open flame or excessive heat
a n d don't smoke when using it. Failure to do so could cause serious
injury. If you become dizzy while using cleaning solvent, get fresh
air and medical attention immediately. If contact with skin or
c l o t h e s is made, flush with large amounts of water. If contact with
e y e s is made, wash eyes with water and get medical aid immediately.
WARNING
Wear safety glasses when drying parts with compressed air. Failure
to do so could cause serious injury to eyes and possible blindness.
If you hurt your eyes or if a foreign object is blown into your
eyes, seek medical attention immediately.
14
All parts
Clean
U s e cleaning solvent P-D-680;
d r y with compressed air
3-246
Change 2