TM 10-3930-638-24&P
3-30. HYDRAULIC LIFT SYSTEM MAINTENANCE (cont)
a. Control Valve (cont)
STEP
LOCATION
ITEM
REMARKS
ACTION
LIFT VALVE SECTION REASSEMBLY (cont)
Install
d. Back-up ring (31)
(cont)
e. O-ring (30)
Install
f. Back-up ring (29)
Install
g. Plug (28)
Install
42
Housing (36),
Conversion plug assembly
Install
bottom
(27)
43
Housing (36),
a. O-ring (26)
Position
On plug (25)
rear
b. Plug (25)
Install
44
a. O-ring (23)
Check plug (24)
Install
On check plug (24)
b. Back-up ring (22)
Install
c. O-ring (21)
Install
d. Back-up ring (20)
Install
e. O-ring (19)
Install
f. Back-up ring (18)
Install
g. Poppet spring (17)
Install
h. Load check poppet (16)
Install
45
Housing (36),
Load check plug assembly Install
top
(15)
46
a. Two O-rings (7)
Install
On spool (8)
Spool (8)
b. Two back-up rings (6)
Install
Install
c. Two seal retainer plates
(5)
47
a. Spool (8)
Install
Housing (36),
top
Position
b. Seal plate (2)
c. Two screws (1)
Install
48
Install
a. Spring collar (14)
Housing (36),
bottom
b. Return spring (13)
Install
c. Spring collar (12)
Install
d. Spool collar (11)
Install
e. Lock washer (10) and
Install
screw (9)
f. Bonnet (4)
Position
Install
g. Two screws (3)
3-215
|