TM 10-3930-638-24&P
3-24. STEERING SYSTEM MAINTENANCE (cont)
c. Hydraulic Pump Repair (cont).
ITEM
REMARKS
ACTION
LOCATION
STEP
CLEANING
WARNING
Dry cleaning solvent P-D-680 used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
w e l l ventilated area. Avoid contact with skin, eyes and clothes and
don-t breathe vapors. Do not use near open flame or excessive heat
a n d don't smoke when using it. Failure to do so could cause serious
injury. If you become dizzy while using cleaning solvent, get fresh
air and medical attention immediately. If contact with skin or
c l o t h e s is made, flush with large amounts of water. If contact with
e y e s is made, wash eyes with water and get medical aid immediately.
WARNING
Wear safety glasses when drying parts with compressed air. Failure
to do so could cause serious injury to eyes and possible blindness.
If you hurt your eyes or if a foreign object is blown into your
eyes, seek medical attention immediately.
5
All Parts
Clean
U s e cleaning solvent P-D-680.
D r y thoroughly with moisture
free compressed air.
INSPECTION
6
R e p l a c e drive shaft and gear
D r i v e shaft (6)
Inspect
(18) if shaft keyway is
broken, splines chipped or
damaged, or if shaft nicked,
b u r r e d , or worn to less than
0 . 8 7 3 inch diameter in
b u s h i n g areas
7
Inspect
Idler shaft (7)
Replace idler shaft and gear
(20) if shaft nicked, burr-
e d or worn to less than
0 . 0 8 7 3 inch diameter in
b u s h i n g areas
8
G e a r s (18 and 20) Inspect
R e p l a c e gear (18 or 20) and
shaft (6 or 7) if gear teeth
c h i p p e d or broken, gear ends
scored or worn, or if gear
w i d t h is less than 0.732
i n c h . Break sharp edges of
g e a r teeth with emery cloth
3-182 Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |