TM 10-3930-636-24P
2-56. HYDRAULIC LIFT SYSTEM MAINTENANCE (cont)
f. Hoses, Lines and Fittings (cont).
(3) Mast Assembly (cont).
ITEM
REMARKS
ACTION
STEP
LOCATION
REMOVAL (cont)
r . Tube assembly Remove
3 (cont)
(42)
s . T u b e f i t t i n g s Loosen and
disconnect
(43 and 44)
t . Tube assembly Remove
(45)
u. Four nuts (46) Remove
Remove
v . Four elbow
fittings
(47)
w. Four nuts (48) Remove
x . F o u r f i t t i n g s Remove
(49)
CLEANING
WARNING
Dry cleaning solvent P-D-680 used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
w e l l ventilated area. Avoid contact with skin, eyes and clothes and
don't breathe vapors. Do not use near open flame or excessive heat
a n d don-t smoke when using it. Failure to do so could cause serious
i n j u r y . If you become dizzy while using cleaning solvent, get fresh
air and medical attention immediately. I f c o n t a c t w i t h s k i n o r
c l o t h e s is made, flush with large amounts of water. If contact with
e y e s is made, wash eyes with water and get medical aid immediately.
All parts
Clean
U s e cleaning solvent P-D-680
4
INSPECTION
Elbow fittings
Inspect
R e p l a c e i f c r a c k e d , d i s t o r t e d:
5
or threads damaged
(3, 10, 23, 24,
a n d 47), 45 de-
gree fitting
( 3 7 ) , 90 degree
fittings (38
and 39), and
fitting (3B
and 49)
2-440H Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |