TM 10-3930-638-24&P
2-38. TRANSMISSION MAINTENANCE (cont)
a. Transmission Servicing and Inspection (cont).
(3) Air Breather (cont).
ITEM
REMARKS
STEP
LOCATION
ACTION
REMOVAL
Remove
1
Air breather
Transmission
torque converter
housing, top
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and don't breathe vapors. Do not use near open flame or exces-
sive heat and don't smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately. and obtain medical aid immediately.
2
Use cleaning solvent P-D-680
Air breather
Clean
INSPECTION
Air breather
Inspect
Replace if damaged or clogged
3
INSTALLATION
Install
4
Transmission
Air breather
torque converter
housing, top