2-32. HORN AND BACK-UP ALARM MAINTENANCE (cont)
b. Horn Switch.
d. Testing
a. Removal
This task covers:
e. Installation/Replacement
b. Cleaning
c.  Inspect ion
INITIAL SETUP
EQUIPMENT CONDITION
TOOLS
Condition Description
Paragraph
No. 1 Common Organiza-
Engine off.
tional Maintenance Tool Kit
Battery ground cable disconnected.
MATERIALS PARTS
Cleaning Solvent P-D-680
Clean cloths
REMARKS
ACTION
ITEM
LOCATION
STEP
REMOVAL
Depress and rotate counterclockwise to
Remove
a. Cover (1) and
1
Steering column
release from tabs on base plate (7)
button (2)
and wheel
b. Contact cup (3), spring
Remove
(4) and spring
contact (5)
Remove
c. Three tapping screws
(6) and base plate (7)
From column terminal (l I )
Grasp and pull
d. Harness connector (8)
From instrument panel
Remove
e. Grommet (9)
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and don't breathe vapors. Do not use near open flame or
excessive heat and don't smoke when using it. Failure to do so
could cause serious injury. If you become dizzy while using
cleaning solvent, get fresh air immediately, and get medical
attention. If contact with skin or clothes is made, flush with large
amounts of water. If contact with eyes is made, wash eyes with
water immediately, and obtain medical aid immediately.