TM 10-3930-638-24&P
2-29. AUXILIARY PANEL MAINTENANCE (cont)
a. Slave Receptacle (cont).
ITEM
STEP
LOCATION
ACTION
REMARKS
INSPECTION
4
All hardware
Inspect
Replace if worn, or if threads damaged
5
Cables (2 and 3)
Inspect
Replace if insulation frayed, or if
conductors broken
6
Receptacle (7) and
Inspect
Replace if threads damaged, or if
cover (10)
receptacle terminals damaged
7
Rubber insulators (8
Inspect
Replace if cracked or deteriorated
and 9)
INSTALLATION/ REPLACEMENT
8
Left hood support a. Cover (10)
Install
On receptacle (7)
plate, top
b. Rubber insulators (8
Position
On left side panel
and 9) and
receptacle (7)
c. Four screws (6) flat
Install and
washers (5) and
tighten
nuts (4)
d. Cables (2 and 3) and
On receptacle (7)
Install and
two cap screws (1)
tighten
e. Cable connectors and
Use silicone rubber sealer
Seal
cap screws (1)
2-141
|