TM 10-3930-638-24&P
2-28. INSTRUMENT PANEL MAINTENANCE (cont)
d. Lockout Relay (cont).
REMARKS
ITEM
ACTION
LOCATION
STEP
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and don't breathe vapors. Do not use near open flame or
excessive heat and don't smoke when using it. Failure to do so
could cause serious injury. If you become dizzy while using
cleaning solvent, get fresh air immediately, and get medical
attention. If contact with skin or clothes is made, flush with large
amounts of water. If contact with eyes is made, wash eyes with
water immediately, and obtain medical aid immediately.
WARNING
Wear safety glasses when drying parts with compressed air.
Failure to. do so could cause serious injury to eyes and possible
blindness. If you hurt your eyes, seek medical attention
immediately.
2
All hardware
Clean
Use cleaning solvent P-D-680.
Dry thoroughly with compressed air
Wire connectors and
Clean
Use cleaning solvent P-D-680 on
3
connectors and terminals only
relay terminals
INSPECTION
Inspect
4
Nut (2) and screw (4)
Replace if threads damaged
Inspect
Replace if insulation frayed, or if
Harness wires
5
conductors broken
Inspect
Relay (5)
Replace if terminals damaged
6
INSTALLATION
7
Instrument panel,
a. Lockout relay (5)
Position
Against instrument panel
Install and
bottom center
Until lockout relay (5) is securely mounted
b. Two screws (4), lock
tighten
washers (3) and
nuts (2)
Relay terminals (note tags for correct
c. Wire leads (1)
Push on
connection)
2-136
|