Click here to make tpub.com your Home Page

Page Title: Flood Light Switches and Circuit Breakers (cont).
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-638-24&P
2-28. INSTRUMENT PANEL MAINTENANCE (cont)
a. Flood Light Switches and Circuit Breakers (cont).
ITEM
REMARKS
ACTION
LOCATION
STEP
CLEANING (cont)
4
Screws (1)
Clean
Use cleaning solvent P-D-680.
Dry thoroughly with compressed air
INSPECTION
5
Rubber boot (3)
Inspect
Replace if threads damaged, or if boot
cracked or deteriorated
6
Replace if insulation frayed, or if
Harness and circuit
Inspect
breaker wires
conductors broken
7
Switch (4)
Inspect
Replace if threads or terminals damaged
INSTALLATION
8
Instrument panel,
a. Circuit breaker lead,
Install and
Note tags for connection
left of steering
wire leads and two
tighten
screws (1)
column
In instrument panel
Position
b. Switch (4) and
washer (5)
c. Rubber boot (3)
Install and
Until switch (4) is securely mounted
tighten
Push in
Harness lead
d. Circuit breaker lead
Loop and tie
e. Tie strap (6)
Around harness wire (to prevent circuit
breaker from hanging)
Seal
Use silicone rubber sealer
f. Wire leads and switch
terminals
2-129