2-27. STARTING SYSTEM MAINTENANCE (cont)
a. Starter (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
TESTING (cont)
d. RPM indicator
Observe indica-
RPM indicator indicates 8000 to
(cont)
tion
13,000 RPM
NOTE
If ammeter does not indicate 52 to 90 amperes, or RPM indicator
does not indicate 8000 to 13,000 RPM, record voltage, current
and RPM, and forward test results with defective starter to
direct support maintenance. If ammeter indicates 52 to 90
amperes and RPM indicator indicates 8000 to 13,000 RPM,
proceed to step 8e.
e. Starter
a. Disconnect
from test set-
up
b. Disconnect
and tape
field coil lead
at solenoid
M terminal
c. Connect
minals to test
setup as
shown
f. Switch
Close
g. Carbon pile
Adjust for 9 Vdc
indication on
h. Ammeter
Observe
Ammeter indicates 6.5 to 7.0 amperes
indication
NOTE
If ammeter does not indicate 6.5 to 7.0 amperes, record test
results and forward to direct support maintenance with defective
starter (solenoid switch defective).