2-17. COOLING SYSTEM MAINTENANCE (cont)
a. Radiator Servicing (cont).
ACTION
STEP
ITEM
LOCATION
REMARKS
SERVICING (cont)
WARNING
4
(cont)
Wear safety glasses when drying parts with compressed air. Failure
to do so could cause serious injury to eyes and possible blindness.
If you hurt your eyes or if a foreign object is blown into your eyes,
seek medical attention immediately.
b. Clean
Use compressed air to clean exterior and
to remove foreign matter obstructing
passage of air through radiator
c. Fill
Use solution of 50 percent water and 50
percent ethylene glycol. Capacity is
16 quarts. Fill with coolant solution
to two inches below level of radiator
cap opening
a. Install
Operate engine for 15 minutes. Check for
b. Radiator
coolant leaks at drain plug and drain
cap
cock; tighten if necessary
b. Remove and
Check coolant level, add if necessary
reinstall
a. Remove cap
Fill recovery tank half full with solution
c. Coolant recov-
of 50 percent water and 50 percent
ery tank
ethylene glycol
b. Install cap
Position
On radiator shroud
Until cover plate is securely mounted
Install and
tighten
d. Cover plate
e. Two lock
washers and
cap screws
2-78