TM 10-3930-631-12
Section II. MAINTENANCE ALLOCATION CHART
(1)
(2)
(3)
(4)
(5)
(6)
GROUP
MAINTENANCE
MAINTENANCE LEVEL
TOOLS AND
NUMBER
COMPONENT ASSEMBLY
FUNCTION
C
O
F
H
D
EQUIPMENT REMARKS
4010
Master or Auxiliary Con-
trol Assembly (Cont'd)
Contactor Panel
Replace
0.5
Assembly
Repair
3. 0
Electromagnetic Relay,
Replace
1.0
Emergency Cutout
Repair
1.0
Electromagnetic Relay,
Replace
0.2
Hydraulic Pump Cutout
Repair
1.0
Insulation Plate
Replace
0.2
Bus Bars
Replace
0.2
Panel Shelf
Replace
0.3
Emergency Cutout Push
Replace
0.2
Switch
Forward and Reverse
Inspect
0.2
2
Contactor Assembly
Replace
0.8
Repair
0.4
4012
Switches
Bracket Assembly
Replace
1.0
Repair
1.0
4014
Resistors
Electronic Components
Test
0.7
2
Replace
0.6
Repair
0.5
Fixed Resistor
Test
0.5
2
Replace
0.3
Change 2 B-10
|