TM10-3930-628-12
Section IV. TROUBLESHOOTING
3-1. Each malfunction stated is followed by a list of
3-6.
General
probable cause of the trouble.
The corrective action
This section provides information useful in
recommended is
described opposite the probable
probable causes of the trouble. The
cause.
corrective diagnosing and correcting unsatisfactory
operation
action recommended is described
opposite the or failure of the fork lift truck and its
components. probable cause. Malfunctions which may
occur are listed in chart
Chart .3-1. Troubleshooting
Malfunction
Probable cause
Corrective action
1.
Truck does not move when ac
a. Emergency stop switch depressed.
a. Reset emergency stop switch.
celerator is depressed.
b. Loose or defective battery
h. Inspect receptacle and connect if
receptacle, loose.
2.
Tilt and lift mechanism does not
a. Emergency stop switch depressed.
a. Reset emergency stop switch.
operate when levers are ac-
b. Loose or defective battery
h. Inspect receptacle and connect if
luated.
receptacle.
loose.
3.
Head and taillights do not operate
a. Emergency stop switch depressed.
a. Reset emergency) stop switch.
when switch is actuated.
b. Loose or defective battery
h. Inspect receptacle and connect if
receptacle.
loose.
c. Loose wiring to lights.
c. Tighten loose connections.
4.
Horn does not sound.
Emergency stop switch depressed.
Reset emergency stop switch.
3-2
|