3-1.
Air Cleaner
The oil bath type air cleaner is mounted on the left side hood support angle. To service the air cleaner proceed as follows:
a.  Loosen and remove the wingnut and washer that secures the air cleaner to the bottom of the angle.
b.  Lift air cleaner baffle and air cleaner top from lower body.
c.  Empty oil from lower body and clean body with solvent-saturated cloth. Dry thoroughly.
d.  Fill lower body to indicated level with clean engine oil of the type used in the engine crankcase.
e.  Position air cleaner and baffle in place and secure with washer and wingnut.
3-6