|
|
NOTES:
1. FOR
OPERATION
OF
EQUIPMENT
IN
and transmission in neutral, add oil to bring oil level to
PROTRACTED COLD TEMPERATURES BELOW -
"FULL" mark. Operate for 5 minutes and check for
150F (-260C). Remove lubricants prescribed in Key for
leaks.
temperatures above -150F (-260C). Relubricate with
lubricants specified in Key for temperatures below -150F
7. TRANSMISSION AND TORQUE CONVERTER OIL
(-260C). If OEA lubricant is required to meet the
FILTER. Each 1000 hours, remove filter, clean filter
temperature ranges prescribed in the Key, OEA lubricant
mount, and install new filter and seal. Fill transmission to
is to be used in place of OE/HDO-10 lubricant for all
low mark. With engine running at idle speed, oil at
temperature ranges where OE/HDO-10 is specified in
operating temperature and transmission in neutral, add
the Key.
oil to bring oil to "FULL" mark. Operate for 5 minutes
and check filter for leaks.
2. OIL CAN POINTS. Each 250 hours lubricate shift
linkage, control valve linkage, brake linkage, and all
8. HYDRAULIC OIL FILTER.
Each 1000 hours,
exposed adjusting threads with OE/HDO.
remove element, clean filter shell and install new
element. After replacement, operate hydraulic system
3. ENGINE OIL LEVEL HOT OR COLD CHECK. Cold
for 5 minutes, check for leaks, check level and bring to
engine, oil level should be at high mark on dipstick. Hot
"FULL" mark.
engine, oil level must be between high and low marks on
dipstick (allow to set 5 minutes before checking).
9. DISTRIBUTOR. Each 500 hours, lubricate rotor
wick with 3 or 4 drops of OE/HDO 10. Apply very light
4. ENGINE. Oil is to be changed each 250 hours.
coat of GAA to breaker cam.
Drain when lubricant is warm.
10. WHEEL BEARINGS. Each 1000 hours, remove
5. ENGINE OIL FILTER. Each 250 hours, remove filter
wheels, inspect all parts, replace damaged or worn parts,
element, clean housing and Install new filter element.
repack bearings, and assemble.
After Installing new filter element, fill crankcase, operate
engine for 5 minutes, check housing for leaks, check
11. AIR CLEANER. Fork Lift Model MHE-209 has oil
crankcase oil level and bring to "FULL" mark.
bath type air cleaner.
Each 10 hours refill air reservoir to level mark. Each 50
6. TRANSMISSION AND TORQUE CONVERTER.
hours disassemble entire unit, clean, re-oil and
Check level each 50 hours with engine running at idle
assemble.
speed, oil at operating temperature and transmission in
neutral. Maintain oil level at "FULL" mark. Change oil
Fork Lift Model MHE-224 has dry type air cleaner. Each
each 1000 hours. Access to torque converter drain plug
250 hours replace element.
Is gained through timing cover opening on engine
flywheel housing. Rotate flywheel until drain plug Is in
12. HYDRAULIC RESERVOIR FILL AND LEVEL CAP.
opening, remove plug and rotate flywheel until plug
Fork Lift Model MHE-209, remove floor plate to check oil
opening is aligned with drain opening at bottom of
level.
flywheel housing. Fill transmission to low mark. Run
engine at idle speed to fill converter and lines. With
Fork Lift Model MHE-224, open door on floor plate to
engine running at idle speed, oil at operating temperature
check oil level.
13. TRANSMISSION AND TORQUE CONVERTER FILL
AND LEVEL CAP. Fork Lift Model MHE-209, remove
floor plate to check oil level.
TA 219935
LO 10-3930-621-21
CARD 6 OF 7
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |