LO 10-3930-620-12
NOTES - CONTINUED:
parts, replace damaged or word parts, repack bearings, and assemble.
4. HYDRAULIC RESERVOIR AND FILTER Refer to TM 10-3930-620-12 for initial filter change interval. Each 50
hours check level. Maintain oil level at "FULL" mark. Each 1000 hours drain reservoir, replace filter element, clean
suction line screen, reinstall drain plug and fill reservoir. Operate lift for 5 minutes, check for leaks, check oil level
and bring to "FULL" mark.
5. HYDRAULIC OIL FILTER. Each 250 hours, remove filter element, filter shell housing and install new element. After
replacement, operate lift for 5 minutes, check for leaks, check oil level and bring to "FULL" mark.
6. DRIVE AXLE. Each 250 hours check level. Change gear lubricant only when required by maintenance repair action,
contamination by water, or other foreign material. After refill, operate for five minutes, check for leaks and bring oil
level to level plug opening.
Copy of this Lubrication Order will remain with the
7. LUBRICANTS. The following is a list of lubricants
equipment at all times, instructions contained herein are
with military symbols and applicable specification
mandatory
numbers.
OE/HDO
MIL-L-2104
By order of the Secretary of the Army:
GO
MIL-L-2105
GAA
MIL-G-10924
JOHN A. WICKHAM, JR.
OEA
MIL-L-46167
General, United States Army
BFS
MIL-B-46176
Chief of Staff
(SD), Type II
P-D-680
OFFICIAL:
ROBERT M. JOYCE
Major General, United States Army
The Adjutant General
DISTRIBUTION:
To be distributed in accordance with DA Form 12-25A,operational Maintenance requirements for Warehouse Equipment.
U.S. Government Printing Office: 1984-420-903/260
Card 5 of 5
|