Installation - TM-10-3930-673-20-20175
Up
TM-10-3930-673-20-2 All Terrain Lifter Army System (ATLAS) 10 000 lb Capacity Manual
Next
ENGINE START SWITCH REPLACEMENT
TM 10-3930-673-20-2
8-7. TOGGLE AND PUSHBUTTON SWITCHES REPLACEMENT (CONT)
5
1
3
2
6
1
2
4
TR00821
3
(2)
Connect electrical wires (1) on switch (2).
NOTE
Number of electrical wires will be different for different switches.
(a)
For switches with screw type terminals, install electrical wires (1) on terminals (6) of switch (2) with screws
(5).
(b)
For switches with spade type terminals, install connectors (3) of electrical wires (1) on terminals (4) of
switch (2).
NOTE
Follow-on Maintenance
Install left and/or right-hand instrument panel (Para 8-5).
Connect negative battery cable (Para 8-44).
END OF TASK
8-22