Click here to make tpub.com your Home Page

Page Title: NONE OF THE GAGES OPERATE - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-20-1
Remove rings bracelets watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on
equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock.
Battery acid is harmful to skin and eyes. Always wear eye protection when working with batteries.
VOLTAGE TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(2) Remove four screws and access panel.
(3) Set multimeter to volts dc.
(4) Connect multimeter positive lead (+) to
wire 9 where wire 9 connects to circuit
breaker CB6.
(5) Connect multimeter negative lead () to
known good ground.
(6) Connect negative battery cable to
negative side of battery (Para 8-42).
ACCESS
P
(a) If 24 vdc is present, go to Step 3 of
ANEL
this fault.
SCREW
(b) If 24 vdc is not present, go to
Step 8 of this fault.
(7) Disconnect negative battery cable from
negative side of battery (Para 8-42).
WIRE 9
CIRCUIT BREAKER CB6
TR01546
2-509