LOW OIL PRESSURE INDICATOR DOES NOT OPERATE.
TM 10-3930-673-20-1
HIGH WATER TEMP
RESISTANCE CHECK
WIRE 14
INDICATOR
(1) Remove cover and disconnect resistor
SOCKET
from connector.
WIRE 10
(2) Attach multimeter positive lead (+) to
RESISTOR
COVER
resistor at circuit breaker side.
(3) Attach multimeter negative lead () to
resistor at light side.
HIGH WATER
(a) If 1500 ohms resistance is
TEMP
measured, replace wire 10
INDICATOR
(Para 8-48).
SCREW
(b) If 1500 ohms resistance is not
measured, replace resistor
PANEL
(Para 8-9).
TR01604
2-393