Click here to make tpub.com your Home Page

Page Title: BLACKOUT STOPLIGHTS DO NOT OPERATE - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-673-20-1
19. BLACKOUT STOPLIGHTS DO NOT OPERATE (CONT).
2
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING on
Bulb OK.
Voltage test.
following page.
STE/ICE-R #89.
POSSIBLE PROBLEMS
REASON FOR QUESTION
Is 24 vdc present at faulty
Connector P2 faulty.
Connector J2 faulty.
This question eliminates possible
blackout brake light socket?
Wire 9 faulty.
problems and determines where
Circuit breaker CB6 faulty.
troubleshooting continues.
Wire 1 faulty.
Run relay faulty.
Wire 3 faulty.
Circuit breaker CB4 faulty.
Wire 40 faulty.
Blackout light switch faulty.
Wire 41 faulty.
Brake switch faulty.
Go to Step 3 of this
Wire 42 faulty.
NO
fault.
Wire 44 faulty.
Connector J1 faulty.
Connector P1 faulty.
YES
Socket(s) faulty.
Go to Step 17 of
this fault.
3
KNOWN INFO
TEST OPTIONS
Bulb OK.
Voltage test.
Is 24 vdc present at starter
STE/ICE-R #89.
POSSIBLE PROBLEMS
motor solenoid where wire 9
REASON FOR QUESTION
Connector P2 faulty.
connects?
Connector J2 faulty.
If 24 vdc is not present, service or
Wire 9 faulty.
replace battery cable.
Circuit breaker CB6 faulty.
Wire 1 faulty.
Run relay faulty.
Wire 3 faulty.
Circuit breaker CB4 faulty.
Wire 40 faulty.
Blackout light switch faulty.
Wire 41 faulty.
Brake switch faulty.
Service or replace
NO
Wire 42 faulty.
battery cable
Wire 44 faulty.
(Para 8-42).
Connector J1 faulty.
Connector P1 faulty.
YES
Socket(s) faulty.
2-346

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business