TM-10-3930-673-20-1 All Terrain Lifter Army System (ATLAS) 10 000 lb Capacity Manual
Next
ALL FLOODLIGHTS DO NOT OPERATE - continued - TM-10-3930-673-20-10287
TM 10-3930-673-20-1
13. ALL FLOODLIGHTS DO NOT OPERATE (CONT).
6
KNOWN INFO
TEST OPTIONS
Ground OK.
Voltage test.
Is 24 vdc present at run relay
Connector P2 OK.
STE/ICE-R #89.
K1 where wire 1 connects?
Connector J2 OK.
REASON FOR QUESTION
Wire 9 OK.
If voltage is not present, wire 1
Circuit breaker CB6 OK.
faulty.
POSSIBLE PROBLEMS
Wire 1 faulty.
Run Relay K1 faulty.
Wire 3 faulty.
Relay K2 faulty.
Wire 5 faulty.
Circuit breaker CB7 faulty.
Wire 70 faulty.
Repair wire 1 (Para
NO
8-48).
YES
7
KNOWN INFO
TEST OPTIONS
Ground OK.
Voltage test.
Is 24 vdc present at run relay
Connector P2 OK.
STE/ICE-R #89.
K1 where wire 3 connects?
Connector J2 OK.
REASON FOR QUESTION
Wire 9 OK.
If voltage is not present, run relay
Circuit breaker CB6 OK.
K1 faulty.
Wire 1 OK.
POSSIBLE PROBLEMS
Run Relay K1 faulty.
Wire 3 faulty.
Relay K2 faulty.
Wire 5 faulty.
Circuit breaker CB7 faulty.
Wire 70 faulty.
Replace run relay
NO
(Para 8-23).
YES
2-234