Quantcast ALL TURN SIGNALS DO NOT OPERATE - continued - TM-10-3930-673-20-10252

 

Click here to make tpub.com your Home Page

Page Title: ALL TURN SIGNALS DO NOT OPERATE - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
ALL TURN SIGNALS DO NOT OPERATE - continued - TM-10-3930-673-20-10251
Up
TM-10-3930-673-20-1 All Terrain Lifter Army System (ATLAS) 10 000 lb Capacity Manual
Next
ALL TURN SIGNALS DO NOT OPERATE - continued - TM-10-3930-673-20-10253
TM 10-3930-673-20-1
10. ALL TURN SIGNALS DO NOT OPERATE (CONT).
4
KNOWN INFO
TEST OPTIONS
Ground OK.
Voltage test.
Is 24 vdc present at
STE/ICE-R #89.
POSSIBLE PROBLEMS
connector P2-1 and known
REASON FOR QUESTION
Connector P2 faulty.
good ground?
Connector J2 faulty.
If voltage is not present at P2-1,
Wire 9 faulty.
wire 9 and/or connector P2 faulty.
Circuit breaker CB6 faulty.
Wire 1 faulty.
Relay K4 faulty.
Wire 29 faulty.
Circuit breaker CB10 faulty.
Wire 24 faulty.
Flasher faulty.
Wire 26 faulty.
Wire 25 faulty.
Repair wire 9 or
NO
Turn signal switch faulty.
connector P2
Wire 27 faulty.
(Para 8-49).
Connector P1 faulty.
Connector J1 faulty.
YES
5
KNOWN INFO
TEST OPTIONS
Ground OK.
Voltage test.
Is 24 vdc present at circuit
Connector P2 OK.
STE/ICE-R #89.
breaker CB6 where wire 9
POSSIBLE PROBLEMS
REASON FOR QUESTION
connects and known good
Connector J2 faulty.
If voltage is not present at circuit
ground?
Wire 9 faulty.
breaker CB6, wire 9 and/or
Circuit breaker CB6 faulty.
connector J2 faulty.
Wire 1 faulty.
Relay K4 faulty.
Wire 29 faulty.
Circuit breaker CB10 faulty.
Wire 24 faulty.
Flasher faulty.
Wire 26 faulty.
Wire 25 faulty.
Repair wire 9 or
NO
Turn signal switch faulty.
connector J2
Wire 27 faulty.
(Para 8-48).
Connector P1 faulty.
Connector J1 faulty.
YES
2-200