Remove rings bracelets watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on
equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock.
Battery acid is harmful to skin and eyes. Always wear eye protection when working with batteries.
VOLTAGE TEST
S
TURN
C FEMALE
(1) Remove battery cover (Para 8-42).
IGNAL
ONNECTOR
(2) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(3) Set multimeter to volts dc.
C
MALE
(4) Connect multimeter positive lead (+) to
ONNECTOR
female connector at faulty turn signal.
(5) Connect multimeter negative lead () to
ground for turn signal.
(6) Connect negative battery cable to
negative side of battery (Para 8-42).
(7) Turn engine start switch to ON position,
BUT DO NOT START ENGINE
GROUND
(TM 10-3930-673-10).
(a) If 24 vdc is present, go to Step 2 of
this fault.
(b) If 24 vdc is not present, go to
Step 3 of this fault.
(8) Turn engine start switch to OFF
position (TM 10-3930-673-10).
TR01721
(9) Disconnect negative battery cable from
negative side of battery (Para 8-42).