7. STOPLIGHT(S) DO NOT OPERATE (CONT).
6
KNOWN INFO
TEST OPTIONS
Bulbs OK.
Voltage test.
Is 24 vdc present at run relay
Connector P2 OK.
STE/ICE-R #89.
K1 where wire 1 connects?
Connector J2 OK.
REASON FOR QUESTION
Wire 9 OK.
If 24 vdc is not present, wire 1
Circuit breaker CB6 OK.
faulty.
POSSIBLE PROBLEMS
Wire 1 faulty
Run relay faulty.
Wire 3 faulty.
Circuit breaker CB4 faulty.
Wire 40 faulty.
Blackout light switch faulty.
Wire 41 faulty.
Brake switch faulty.
Repair wire 1 (Para
NO
Wire 42 faulty.
8-48).
Wire 43 faulty.
Connector J1 faulty.
Connector P1 faulty.
YES
Socket(s) faulty.
7
KNOWN INFO
TEST OPTIONS
Bulbs OK.
Voltage test.
Is 24 vdc present at run relay
Connector P2 OK.
STE/ICE-R #89.
K1 where wire 3 connects?
Connector J2 OK.
REASON FOR QUESTION
Wire 9 OK.
If 24 vdc is not present, run relay
Circuit breaker CB6 OK.
faulty.
Wire 1 OK.
POSSIBLE PROBLEMS
Run relay faulty.
Wire 3 faulty.
Circuit breaker CB4 faulty.
Wire 40 faulty.
Blackout light switch faulty.
Wire 41 faulty.
Brake switch faulty.
Replace run relay
NO
Wire 42 faulty.
(Para 8-23).
Wire 43 faulty.
Connector J1 faulty.
Connector P1 faulty.
YES
Socket(s) faulty.
2-144