Quantcast Table 2-1. Unit Preventive Maintenance Checks and Services - continued - TM-10-3930-673-20-10048

 

Click here to make tpub.com your Home Page

Page Title: Table 2-1. Unit Preventive Maintenance Checks and Services - continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
Table 2-1. Unit Preventive Maintenance Checks and Services - continued - TM-10-3930-673-20-10047
Up
TM-10-3930-673-20-1 All Terrain Lifter Army System (ATLAS) 10 000 lb Capacity Manual
Next
Table 2-1. Unit Preventive Maintenance Checks and Services - continued - TM-10-3930-673-20-10049
TM 10-3930-673-20-1
Table 2-1. Unit Preventive Maintenance Checks and Services (Continued)
Location
Item
Item to Check/
No.
Interval
Service
Procedure
LUB(E POINTS
(  GAA)
3 PLACES)
TR00973
Do not stand under the attachment and carriage assembly during
lubrication servicing. Failure to comply may result in serious
injury or death to personnel.
Lubricate daily during periods of high cycling or high loading.
Weekly
Lubricate carriage tilt cylinder rod end pin with GAA as required. To
access carriage lube points and tilt cylinder lower points, raise fork
assembly 48 inches (122 cm) and tilt carriage assembly forward 90.
To access tilt cylinder rod end pin, place level fork/carriage assembly
firmly on the ground.