TM 10-3930-671-24 6. DRAIN WATER FROM FUEL FILTER(S) Note:    Some  fuel  filters  are  not  equipped  with  a  water drain (See Fuel Filters, Section 5). 7. ADJUST IDLE SPEED TO EQUIPMENT MANUFACTURERS RECOMMENDATION Repeat again at end of 500 hours. EVERY 250 HOURS 1. REPEAT DAILY & 50-HOUR SCHEDULES Follow previous Instructions. 2. CLEAN EXTERIOR OF ENGINE Use  steam  if  available,  otherwise  any  good  commercial engine cleaner to wash down the engine. CAUTION Never   allow   cool   water   to   come   in contact  with  the  fuel  injection  pump while the engine Is running! Injection pump seizure may result. 3. CHECK GLOW PLUGS Inspect glow plug wiring. 4. IF DRY REPLACEABLE ELEMENT AIR CLEANER IS USED, REPLACE ELEMENT 5. FIRST 250 HOURS RECOMMEND ADJUSTING VALVE TAPPET CLEARANCE EVERY 400 HOURS 1. REPEAT DAILY AND 50-HOUR SCHEDULES Follow previous Instructions. 2. FUEL SYSTEM (See fuel filters Section 5) -Replace fuel filter element. -Inspect mounting and gaskets. -Check all connections for leaks. 1. REPEAT   DAILY   50   HOUR   AND   250   HOUR SCHEDULES 2. COOLING SYSTEM Clean radiator core by blowing out with compressed air. -Inspect radiator mounting. -Inspect water pump and connections for leaks. -Check fan and accessory drive belts. EVERY 500 HOURS 3. ADJUST VALVE TAPPET CLEARANCE Check  and  adjust  intake  and  exhaust  valve  tappets  to following clearances at operating temperature. MODEL INTAKE EXHAUST TMD 0.36mm 0.46mm (.014") (.018’) 4. SAFETY AND THERMAL CONTROLS Inspect control wires and connections. F-166