TM 10-3930-669-20 (2) Assembly. (a)   Strip  end  of  wire  (5)  leaving  1/4  in.    (0.64 cm) of bare wire. NOTE Wire  should  be  positioned  so  larger wings  of  terminal  will  crimp  around insulation    and    smaller    wings    will crimp around exposed bare wire. (b)   Push  terminal  (3)  open  and  position  wire (5). (c)   Crimp terminal (3) on wire (5). (d)   Install conduit (4) on wire (5). (e)   Install terminal (3) in connector (1). (f) Connect   front   worklight   connector   (2)   on connector (1). c. Type III Connector Repair. (1) Disassembly. (a)   Disconnect connector (1). (b)   Using terminal removal tool, remove terminal (2) from connector (1). (c)   Cut and remove terminal (2) from wire (3). 7-136