TM  10-3930-669-20 WARNING Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry contacts battery terminal, a direct short may result in instant heating of tools, damage to equipment, and injury or death to personnel. VOLTAGE TEST (1) Remove oil filter tray (Para 4-13).  Do not disconnect hoses or wires. (2) Disconnect  connector  P18  from  axle oil pump connector. (3) Set multimeter select switch to VOLTS DC. (4) Connect  positive  (+)  multimeter  lead to connector P18, terminal 1. (5) Connect  negative  (-)  multimeter  lead to a known good ground. (6) Turn   Main   power   switch   to   the   ON position (TM 10-3930-669-10). (a)   If   there   are   not   22   to   24   vdc present,  perform  Step  (7)  below and go to Step 18 of this Fault. (b)   If there are 22 to 24 vdc present, perform Step (7) below and go to Step 17 of this Fault. (7) Turn  Main  power  switch  to  the  OFF position. 2-363