TM 10-3930-669-20 WARNING Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry contacts battery terminal, a direct short may result in instant heating of tools, damage to equipment, and injury or death to personnel. VOLTAGE TEST (1)   Remove floor plate (Para 15-12). (2)   Disconnect connector P11 from transmission control connector. (3)   Set  multimeter  select  switch  to  VOLTS DC. (4)   Connect  positive  (+)  multimeter  lead  to connector P11, terminal 3. (5)   Connect negative (-) multimeter lead to a known good ground. (6)   Set     MAIN     POWER     switch     to     ON position (TM 10-3930-669-10). (7)   Set   engine   switch   to   ignition   position (TM 10-3930-669-10). (8)   Set transmission control lever to forward position (TM 10-3930-669-10). (a)   If    there    are    not    22    to    24    vdc present,  perform  Steps  (9)  through (12)  below  and  go  to  Step  2  of  this Fault. (b)   If  there  are  22  to  24  vdc  present, forward   control   solenoid   is   faulty. Perform    Steps    (9)    through    (12) below and Notify DS Maintenance. (9)   Set transmission control lever to neutral position. (10)   Set engine switch to off position. (11)   Set    MAIN    POWER    switch    to    OFF position. (12)   Install floor plate (Para 15-12). 2-251