TM 10-3930-669-20 WARNING Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry contacts battery terminal, a direct short may result in instant heating of tools, damage to equipment, and injury or death to personnel. VOLTAGE TEST (1) Remove floor plate (Para 15-12). (2) Disconnect connector P16 from horn. (3)   Set multimeter select switch to VOLTS DC. (4)   Connect positive (+) multimeter lead to connector P16, terminal 1. (5) Connect negative (-) multimeter lead to a known good ground. (6)   Set MAIN POWER switch to ON position (TM 10-3930-669-10). (7)   Set engine switch to ignition position (TM 10-3930-669-10). (a) If there are not 22 to 24 vdc present, perform Steps (8) through (11) below and go to Step 3 of this Fault. (b) If there are 22 to 24 vdc present, perform Steps (8) through (9) below and go to Step 2 of this Fault. (8) Set engine switch to off position. (9) Connect connector P16 to horn. (10) Set MAIN POWER switch to OFF position. (11) Install floor plate. CONTINUITY TEST (1) Disconnect connector P16. (2) Set multimeter select switch to OHMS. (3) Depress horn switch and check continuity between connector P16, terminal 2 and a known good ground. (a) If there is no continuity, perform Steps (4) and (5) below and go to Step 4 of this Fault. (b) If there is continuity, replace horn (Para 7-45). (4) Connect connector P16. (5) Install floor plate (Para 15-12). 2-209