TM 10-3930-669-20 WARNING Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry contacts battery terminal, a direct short may result in instant heating of tools, damage to equipment, and injury or death to personnel. VOLTAGE TEST (1)   Remove instrument panel (Para 7-8). (2)   Set  multimeter  select  switch  to  VOLTS DC. (3)   Connect  positive  (+)  multimeter  lead  to ammeter, terminal I. (4)   Connect negative (-) multimeter lead to a known good ground. (a)   If    there    are    not    22    to    24    vdc present, repair wire 11 (see schematic Appendix F) (b)   If  there  are  22  to  24  vdc  present, wire 11 is OK. 2-133