TM 10-3930-664-24 10. If    installing    a    new    oil    pump,    measure    gear backlash   (dimensions   D   AND   E).      Backlash limits  for  D  and  E  shall  be  0.003  TO  0.013  in. (0.08 TO 0.33 mm). FOLLOW-ON MAINTENANCE: Install gear cover (para.  3-12) END OF TASK 3-60