TM 10-3930-664-24 6. SHIFT   SIDESHIFT   CARRIER   ALL   THE   WAY   TO THE LEFT TO GAIN ACCESS TO COMPONENTS. 7. REMOVE RIGHT SPLASH GUARD BY REMOVING ATTACHING PARTS. 8. TAG  AND  DISCONNECT  TUBE  ASSEMBLIES  (20, 21)  FROM  SIDESHIFT  CYLINDER  (22).    REMOVE FITTINGS. a. Tag   and   disconnect   tube   assemblies   (20,   21) from elbows (23). b. Remove      elbows   (23)   from   sideshift   cylinder (22).  Remove  and discard O-rings (24). c. Tag   and   disconnect   tube   assemblies   (20,   21) from fitting (25) and elbow (26). d. Remove     fitting     (25)     and     elbow     (26)     from bulkhead bracket (27). 9. TAG AND DISCONNECT HOSE ASSEMBLIES (28, 29) FROM INTERMEDIATE RAIL MANIFOLD (30). 2-423