TM 10-3930-664-24 2 APPLY    LOCTITE    TO    THREADS    OF    NINE TRANSMISSION COVER SCREWS (12).INSTALL    TOP    TRANSMISSION    COVER (11) USING SCREWS AND WASHERS (13). 3 CLOSE    HOOD    ASSEMBLY    (9).    ENSURE HANDLE (10) IS FULLY ENGAGED. 4 CONNECT    HOSES    (1,    4,    7)    TO    HEATER COMPONENTS. a. Connect outlet hose (7) to heater assembly (6) using clamp (8). b. Install   hose   (4)   to   heater   assembly   (6). Secure using clamp (5). c. Install heater shutoff valve (2) to hose (4). Secure using clamp (5). d. Connect  inlet   hose   (1)   to   heater   shutoff valve (2) using clamp (3). FOLLOW-ON MAINTENANCE: Raise towbar and lock in position (para.  2-126) Service radiator assembly (para.  2-46) END OF TASK 2-388