TM 10-3930-664-24 2-86.  DCA WIRING HARNESS REPLACEMENT This task covers: Removal, Cleaning, Inspection, and Installation INITIAL SETUP: Tools and Test Equipment: Equipment Condition: General Mechanics Tool Kit (1, App.  E) Batteries disconnected (para.  2-78) Materials / Parts: Loctite 242 (20, App.  C) A.  REMOVAL WARNING Electrical  shock  hazard.    Disconnect battery ground cable or power source prior to working on electrical components.  Failure to heed warning could cause shock, injury or death.  If electrical    shock    occurs,    administer first aid and  seek  medical  assistance immediately. 1. Refer   to   Figure   FO-4,   DCA   Wiring   Harness,   for information on wires and contact points. 2. Tab   wire    leads    before    disconnecting    to    aid    in assembly. 3. Remove   top   transmission   cover   (1)   by   removing nine screws (2) and washers (3). 4. Remove     DCA     connector     (4)     from     right     side transmission   cover   by   removing   screws   (5)   and washers (6). B.  CLEANING Clean DCA wiring harness and components in accordance with paragraph 1-24. 2-250