TM 10-3930-664-24 2. INSTALL PRESSURE TRANSDUCER (22). a. Install        adapter        (27).            Install        pressure transducer (26) onto adapter. b. Connect      pressure   transducer   electrical   wiring (25). 3. INSTALL RESISTOR ASSEMBLY (19) AND ALTERNATE FUEL SHUTOFF SWITCH (21) ONTO DCA PLATE (10). a. Install alternate fuel shutoff switch (21) onto DCA plate (10) using attaching nut. b. Connect    electrical    wiring    to  resistor  assembly (19).  Connect wires (22, 23, 24) to alternate fuel shutoff switch (21). c. Install resistor assembly (19) onto DCA plate (10) using screws (20). 4. INSTALL   DIFFERENTIAL   PRESSURE SWITCH (9) ONTO DCA PLATE (10). a. Install    fittings    (14)  onto    differential  pressure switch (9).  Install clamps (15). b. Align spacers (16) with holes in DCA plate (10). Secure differential pressure switch (9) onto DCA plate using screws (17) and lockwashers (18). c. Connect    hose    assemblies    (12,    13)  to  fittings (14). d. Connect    differential    pressure    switch  electrical wiring (11). 5. APPLY LOCTITE TO SCREWS (7).  INSTALL TRANSMISSION COVER TOP (6) USING NINE SCREWS (7) AND WASHERS (8). 2-188