TM10-3930-660-34 6-4. STARTER - REPAIR (Cont’d) a. If removed, install field coil (22) and pole shoes (23). Secure pole shoes (23) with eight screws (24).  Use care to prevent grounding or shorting coils as pole shoes are secured. NOTE If supports (16) were removed, use service parts (53) through (55) to secure supports (16) during step b. b. If removed, secure two supports (16),and two brush ground leads (20) with four studs (53), four lockwashers (54), and four nuts (55). c. Install two springs (15), two grounded brush holders (13), two insulated brush holders (14) and two pins (12). d. Install two brushes (19) in grounded brush holders (14).  Secure brushes (19) and brush ground leads (20) using two screws (17). e. Install two brushes (19) in insulated brush holders (13) and secure with two screws (18). f. Install new grommet (11) and connector (2). 6. PLACE BRAKE WASHER (42) ON ARMATURE (9). 7.    CAREFULLY LOWER FIELD FRAME (8) ONTO ARMATURE (9), MAKING CERTAIN THAT BRUSHES (19) CLEAR COMMUTATOR BARS AND NO INTERFERENCE OCCURS BETWEEN POLE SHOES (23) AND ARMATURE (9).INSTALL SCREW (7) TO SECURE CONNECTOR (2) TO FIELD COIL (22) TERMINAL.. 6-17