Page Title: FUEL SHUTOFF SOLENOID TESTING (165 HP)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-660-24-1
FUEL SHUTOFF SOLENOID TESTING (165 HP)
THIS WORK PACKAGE COVERS
Electrical Testing of Shutoff Solenoid
INITIAL SETUP
Personnel Required
Tools and Special Tools
Tool kit, general mechanic's (Item 39, WP 0324 00)
Two
Shop equipment, common no. 1 (Item 20, WP 0324
Equipment Condition
References
Vehicle parked on level ground (TM 10-3930-660-
WP 0227 00
10)
WARNING
DO NOT smoke or permit any open flame in area of vehicle while you are servicing fuel system. Fail-
ure to follow this warning may result in injury or equipment damage.
DO NOT perform fuel system checks, inspections or maintenance while smoking or near fire, flames or
sparks. Fuel may ignite, causing damage to vehicle and injury or death.
NOTE
If fuel shutoff solenoid replacement is required, refer to WP 0227 00.
Ensure engine start switch is in the OFF position during step 1.