TM10-3930-660-20 8-44. BATTERY CABLES AND TERMINALS -  SERVICE/REPLACE  (Cont’d) 3. POSITION NEGATIVE BATTERY CABLE (4) IN BATTERY BOX (3) AND CONNECT CABLE (4) AT STE/ICE SHUNT (37). a. Position negative battery cable (4) inside battery box (3). b. Position short end of negative battery cable (4) on terminal (40) of STE/ICE shunt (37) and secure with capscrew (38) and new lockwasher  (39). 4. INSTALL POSITIVE EMERGENCY STEER PUMP POWER CABLE (29), POSITIVE BATTERY CABLE (11), AND NEGATIVE BATTERY CABLE (4), AT SLAVE RECEPTACLE (30). a. b. c. d. Position negative battery cable (4) on negative terminal (36) of slave receptacle (30). Secure cable (4) to terminal (36) with capscrew (34) and new starwasher (35). Position positive emergency steer Pump power cable (29) and positive battery cable (11) on positive terminal (33) of slave receptacle (30) . Secure cables (29) and (11) with capscrew (31) and new starwasher (32) . 8-121