TM10-3930-660-10 3-8. AIR   CLEANER   -   SERVICE   (Cont.) Always   wear   safety   glasses   whenever compressed   air   is   used.   Do   not   exceed 30  psig  nozzle  pressure  when  using compressed   air. b.   To   remove   remaining   dust,   use compressed  air  under  30  psig.  Blow  the air  up  and  down  the  pleats  from  the inside  of  the  element.  Be  careful  not  to damage  or  tear  paper  element. DO  NOT  wash  element  in  fuel  oil,  oil, gasoline,   or   solvent.   DO   NOT   use compressed  air  to  remove  water  from  an element. c.  To  clean  oily  or  sooty  element,  wash thoroughly   with   warm   water   and nonfoaming   detergent.   Rinse   element with  clean  water  and  allow  element  to air  dry.  Clean  outer  cover  and  rubber evacuator  valve  with  soap  and  water. 4.   INSTALL   PRIMARY   AIR   FILTER   ELEMENT. a. b. c. d. DO  NOT  install  element  until  it  is  dry. Inspect   element   for   damage.   Place   a bright  light  inside  the  element  and  rotate element  slowly.  If  any  rupture,  holes  or damaged   gaskets   are   discovered, replace   the   element. If  a  new  element  is  to  be  installed, inspect  the  element  and  gasket  for shipping   and   storage   damage. Install  the  primary  filter  element  in  the  air cleaner  canister  and  secure  with  the wing   nut. 3-11

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business