TM 10-3930-659-20 16-18.    DATA PLATES REPLACEMENT. This Task Covers: a. Removal b. Installation Initial Setup: Materials/Parts: Tools/Test Equipment: Adhesive (Item 1, Appendix C) •  General mechanic's tool kit (Item 44, Appendix F) Rags (Item 27, Appendix C) •  Electric drill, portable (Item 11, Appendix F) Dry cleaning solvent (Item 31, Appendix C) •  Twist drill set (Item 12, Appendix F) Rivets (quantity will vary) General Safety Instructions: References: •   Dry cleaning solvent is flammable and must not be TM 10-3930-659-10 used near open flame.  Use only in a well-ventilated area. NOTE Refer to TM 10-3930-659-10 for location and description of all data plates. a. REMOVAL NOTE Perform step 1 only if data plate Is secured with rivets.  Quantity of rivets may vary. Loader frame data plate Is illustrated. Perform steps 2 and 3 only if data plate Is secured with adhesive. 1. Remove four rivets (3) and loader frame data plate (2) from loader frame (1).  Discard rivets. 16-60