TM 10-3930-659-20 15-1. ON-BOARD CRANE MAINTENANCE (Con't). 8. If damaged, remove crane cable (2) from wire rope hoist (20). 9. If damaged, remove locknut (23) and handle (22) from wire rope hoist (20).  Discard locknut. c. CLEANING AND INSPECTION WARNING Dry  cleaning  solvent,  P-D-680,  Is  toxic  and  flammable.    Always wear   protective   goggles   and   gloves,   and   use   only   in   a   well- ventilated area.  Avoid contact with skin, eyes, and clothes, and DO NOT  breathe  vapors.    DO  NOT  use  near  open  flame  or  excessive heat.  The solvent's flash point Is 100°F-1380F (38°C-590C).  If you become dizzy while using cleaning solvent, Immediately get fresh air  and  medical  help.  If  solvent  contacts  eyes,  immediately  wash your eyes and get medical aid. 1. Clean all parts with dry cleaning solvent and dry with clean rags. 2. Inspect parts for damage.  Replace damaged parts. d. ASSEMBLY 1. If removed, install handle (22) on wire rope hoist (20) with new locknut (23). NOTE When Installing cable on wire rope hoist, ensure that cable Is evenly wound. 2. If removed, install crane cable (2) on wire rope hoist (20) as illustrated. TA706764 15-6