TM 10-3930-659-20 6-47. SLAVE RECEPTACLE REPLACEMENT. This task covers: a. Removal b. Installation Initial Setup Equipment Conditions: Materials/Parts: Battery disconnect switch in OFF position (see Sealant (Item 29, Appendix C) TM 10-3930-659-10). Marker tags (Item 33, Appendix C) Negative battery cables disconnected - Three lockwashers (see para graph 6-43). Conveyorized fork attachments removed from References: side of forklift truck (see paragraph 17-13). TM 10-3930-659-10 Right engine upper sideshield opened (see TM 10-3930-659-10). Tools/Test Equipment: General mechanic's tool kit (Item 44, Appendix F) a. REMOVAL 1. Remove sealant from rear of slave receptacle (18). 2. Pull back rubber boot (9) and remove screw (8), lockwasher (7), and cable (6) from slave receptacle (18).  Discard lockwasher. 3. Remove screw (1), lockwasher (2), and ground cable (3) from slave receptacle (18).  Discard lockwasher. TA707839 6-161