TABLE 4. TROUBLESHOOTING GUIDE (Continued)
REMEDY
PROBABLE CAUSE
TROUBLE
5. BATTERY, LIGHTS AND HORN
Replace switch.
Defective switch
Light switch
[continued)
Clean, tighten, repair or replace.
Loose or dirty connections;
Wiring
Wire or terminal.
broken wire or terminal
Turn switch "on" fully.
S w i t c h not fully "on"
Lights do not light
Clean and tighten; replace or repair
Loose or dirty connections;
wire or terminal.
broken wire
Correct short circuit or replace
Wiring circuit short-circuited,
defective parts.
or open
Replace light.
Light burned out
Clean and tighten connections.
Loose or dirty connection
Lights dim
Correct short circuit or replace
Wiring
short-circuited
defective parts.
Replace switch.
Defective switch
Clean and tighten connections.
Loose or dirty wiring
Horn troubles
connections
Replace wire.
Short-circuit in wiring between
Horn sounds
horn and horn button
continuously
Clean and tighten connections.
Loose or dirty wiring
Improper tone
connections
Tighten.
Cover or bracket screws loose
Adjust points.
Points adjusted improperly
Replace fuse.
Horn fuse blown
Horn will not operate
Trace, repair or replace as required.
Open circuit
Replace relay.
Faulty horn relay
4-81