TM  10-3930-643-34 GENERAL  SUPPORT  TRANSMISSION  MAINTENANCE. 15-5. Second and Third Gear Assembly. (Sheet 6 of 17) DISASSEMBLY COMPRESSED  AIR  HAZARD Compressed  air  used  for  cleaning purposes will not exceed 30 psi. Use only with effective chip guarding  and  personal  protective 22. 23. 24. 25. equipment (goggles/shield, gloves, etc.). Do not blast piston out of cylinder. Use air pressure with restraint. Failure to follow this procedure could result in damage to piston or cylinder. NOTE Third gear port is closest to the rear of the shaft. Apply air pressure to shaft bore at third gear side. Remove piston (29). Using a machinist’s scribe, remove and  discard  preformed  packing (30) and seal ring (31). Using a machinist’s scribe, remove and discard retaining ring (32). Go to sheet 7 15-61