TM  10-3930-643-34 HYDRAULIC  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 12-10. Boom Assembly. (Sheet 7 of 11) CLEANING/INSPECTION l COMPRESSED  AIR  HAZARD Compressed air used for cleaning purposes will not exceed 30 psi. Use only with effective chip guarding and personal protective equipment  (goggles/shield,  gloves, etc.). 32. Wipe hose assemblies (7 and 12) with clean  cloth  moistened  with  detergent. Dry with compressed air. l TOXIC/FLAMMABLE Dry  cleaning  solvent  P-D-680,  used for cleaning parts, is toxic and flammable. Use only in well ventilated  areas. Wear  protective goggles and gloves. Do not smoke or allow open flames or sparks in areas where cleaning solvent is used or stored, Avoid contact with eyes, skin or clothing. If contact with eyes is made, flush with cold water and seek medical attention  immediately. If contact with skin or clothing is made, flush with cold water. If you become  dizzy  while  using  cleaning solvent, get fresh air immediately. 33. Clean all other parts with cleaning solvent P–D-680. Dry  thoroughly  with compressed air. Refer to paragraph 2-8. Go to sheet 8 12-81